HPLC/UHPLC
HPLC/UHPLCS6000Plus UHPLC
S6000Plus UHPLC
咨询产品信息
■ Biocompatible and salt-resistant check valve design
New ceramic check valve is more salt-resistant and can working better uder high concentration ACN.
■ Binary/Quaternary mixing pump available
Binary gradient pump and Quaternary gradient pump are available, the pump system can be flexibly configured according to the application scenario.
■ Max Pressure limitation 70MPa
The Max pressure reaches 70MPa, which can fully adapt to the application of 2.5um particle size chromatography columns.
Sample Management system
■Sample carryover can reach <0.003%
Innovative inlet design to achieve long life seal and nearly zero carryover.
Special flush flow path and flush solution, are designed to adequately flush the entire injection system.
■Temperature-controlled automatic sampler
The automatic sampler temperature control system uses the peltier temperature control module to accurately stabilize the temperature of the sampler at the set value and ensure the stability of the temperature sensitive sample.
■Flow-through needle injection mode, no sample waste
The autosampler uses a flow-through needle injection mode to avoid the problem of wasting sample, which caused by sample loop injection mode’s necessary part --- "sample overfill", allowing for "as much injecting, as much sampling".
column management system
■Peltier heating / refrigeration, temperature control is more stable
Temperature setting range: 1~90℃ (minimum unit is 1℃).
A 300-mm column can be placed
■Passive preheating function
The mobile phase is pre-heated before entering the column, which reduces the interference to the temperature environment in the column and ensures excellent peak shape symmetry and sharpness and reproducibility.
Rich variety of excellent performance detector
■A variety of detectors, to meet the different needs of users
Specifications
Mixing Mode: |
Binary/Quaternary |
FLow rate range: |
0.001-10.000 ml/min |
Max operate pressure: |
70MPa |
Max Injection volume: |
30ul,can be expended to 100ul |
Temp. Range: |
1-45℃ (Room Temp.-24℃-- Room Temp. +20℃) |
Injector Capacity: |
120 2ml vials, 96-well plates compatible |
Column Oven Temp: |
1-90℃(Room Temp. -24℃--Room Temp. +65℃) |
Column Switch: |
Optional |
Max Column Capacity: |
300mm column, 3 columns |
DAD detector |
1024 diodes |
Wavelength Cal: |
Built-in Hg lamp calibrate |
Max Sampling rate: |
160Hz |
Reference Wavelength: |
Independent mode, different reference wavelength can be set for each channel |
Thank you for your attention and trust in Acchrom Tech products. If you have any questions or abnormal situations with the products during browsing the website, please leave a message or call our company.
Customer Service Hotline :400-108-7908,
We will contact you as soon as possible and wish you and your family happiness and health!